• Trek 30/20A High Voltage Amplifier

Trek 30/20A High Voltage Amplifier

Non-Inverting High Voltage Amplifier, Output Voltage 0 to ±30 kV DC or Peak AC

Advanced Energy's DC-stable Trek 30/20A high voltage amplifier offers a low-noise operation, expansive bandwidth, and a high slew rate. It's ideal for numerous applications including high voltage cable and component testing, and plasma studies.

• Output Voltage: 0 to ±30 kV DC or peak AC
• Output Current: 0 to ±20 mA DC or peak AC
• Slew Rate: Greater than 550 V/µs
• Large Signal Bandwidth: DC to greater than 2.5 kHz (2% distortion)
• Gain: 3000 V/V fixed
Model : Trek 30/20A

The high voltage amplifier Trek® 30/20A is DC-stable and has an all-solid-state design that enables a high slew rate, wide bandwidth, and low-noise operation. It features a non-inverting a fixed gain of 3000 V/V. It is protected against overvoltage and overcurrent conditions generated by active loads or output short circuits to the ground. Precision voltage and current monitors provide low-voltage representations of the high-voltage output and load current for monitoring purposes or feedback signals in a closed-loop system.

Achieve accurate output responses and high slew rates demanded by reactive loads via the four-quadrant active output. It sinks or sources the current to reactive or resistive loads throughout the output voltage range.

Benefits

  • Benefit from a closed-loop system and achieve high accuracy
  • Take advantage of complete solid-state design and maintenance-free operation
  • Rely on ultra-accurate outputs thanks to low-output noise
  • Protect against overvoltage and overcurrent conditions generated by active loads
  • Drive capacitive loads via a four-quadrant output

Dimensions: 103.9 cm H x 43 cm W x 87 cm D (40.9” H x 17” W x 34” D) Depth dimension includes wheels, handles and spacing for air flow. 

Weight: 73 kg (160 lb) approximate 

HV Connector: Caton high-voltage Connector 

BNC Connectors: Amplifier Input, Voltage Monitor, Current Monitor, Remote High Voltage ON/OFF, Out of Regulation Status, Fault/Trip Status

Temperature: 0°C to 40°C (32°F to 104°F) 

Relative Humidity: To 75%, noncondensing 

Altitude: To 1524 meters (5000 ft.)

  • Settling time (to 1%) is less than 200 µs for a 0-30 kV step
  • Dynamically adjust to optimize AC response for various load parameters
  • Local and remote high voltage On/Off capabilities
  • NIST-traceable calibration certificate provided with each unit
  • Short-circuit protection to safeguard equipment
  • Dielectric studies
  • Electron beam ion traps and ion sourcing
  • Electrospinning
  • Electrostatic deflection (including ion beam steering)
  • Electrostatic flame control
  • Electrostatic levitation
  • Electrostatic precipitation
  • High-voltage cable testing
  • High-voltage component testing
  • Plasma studies (including dielectric barrier discharge)

Related Products

Trek 609B-3 High Voltage Amplifier

Trek 609B-3 High Voltage Amplifier

Trek 610E High Voltage Amplifier

Trek 610E High Voltage Amplifier

Trek PD05034 High Voltage Amplifier

Trek PD05034 High Voltage Amplifier

Trek PD07016 High Voltage Amplifier

Trek PD07016 High Voltage Amplifier

Trek 677B High Voltage Amplifier

Trek 677B High Voltage Amplifier

Trek 623B High Voltage Amplifier

Trek 623B High Voltage Amplifier

line

透過行動條碼加入LINE好友

請在LINE應用程式上開啟「好友」分頁,點選畫面右上方用來加入好友的圖示,接著點選「行動條碼」,然後掃描此行動條碼。