• Monroe 287B Charge Plate Ionizer Performance Analyzer
  • Monroe 287B Charge Plate Ionizer Performance Analyzer
  • Monroe 287B Charge Plate Ionizer Performance Analyzer

Monroe 287B Charge Plate Ionizer Performance Analyzer

• All-in-One Instrument-Measures, displays and stores voltage, decay time, temperature and humidity
• Exceeds current requirements of ANSI/ESD SP3.3 for Periodic Verification of Air Ionizers
• Test Balance and Decay
• Low Cost / Performance Ratio
• Hand-held, Battery Operated
• Microprocessor Driven
• Built -in Self Test
• Exclusive Monroe Electronics Two-year Warranty
Model : Monroe 287B

The model 287B is a low-cost and highly portable alternative to a charged-plate monitor for periodic verification of ionzer performance. It permits ionizer testing at the work location without the need to remove the ionizer from service for testing.

Charger:
±1100volts, selectable polarity
Fieldmeter:
Measurement Range:   
±1250V, 1V resolution
Accuracy:
±5% of reading, ±2% typical
Zero Drift:
<±4V in 90s, ±2V typical
Trip Points:
Fixed 1000V and 100V
Charge Plate:
1.7in x 4in; (43mm x 102mm)
Capacitance:
»25pf
Self-discharge:
<10% of full scale in 200s
Display:
2.4” x 0.63”, 2 x 16 LCD
Timer:
200.0s maximum, 0.1s resolution
Sensors:
20-80% ±3% of reading
Humidity
Temperature:
±1°C typical
Oper. Temp.:
25°C, ±10°C
Battery:
9 volt NEDA #1604A or equivalent al- kaline (>40 hour life or >1300 charge cycles). Longer life may be achieved by using 9-volt lithium.
Dimensions:
8.1x4x1.9 inches (206 x 102 x 48 mm)
Weight:
1lb., 6oz. (0.63kg)

  • Manual or automated tests
  • Optional 6-inch plate attachment (Model 287/22C) achieves 1:1 correspondence with standard charged-plate monitor test results
  • Saves the test results for ten manual tests or ten automated test sequences including environmental data
  • Integral temperature and relative humidity sensors to capture environmental data during test
  • Test results correlate to standard tests performed using a charged-plate monitor in accordance with ESD Association standard S3.1
  • Intergrates decay timer lacking in ionizer test kits for fieldmeters

Related Products

Trek 158A charged plate monitor

Trek 158A charged plate monitor

Trek 156A charged plate monitor

Trek 156A charged plate monitor

Monroe 282CPS Charge Plate System

Monroe 282CPS Charge Plate System

Trek 875 Electrostatic Voltage Sensor

Trek 875 Electrostatic Voltage Sensor

Trek 511 hand-held electrostatic field meter

Trek 511 hand-held electrostatic field meter

Trek 157 charged plate monitor

Trek 157 charged plate monitor

line

透過行動條碼加入LINE好友

請在LINE應用程式上開啟「好友」分頁,點選畫面右上方用來加入好友的圖示,接著點選「行動條碼」,然後掃描此行動條碼。